{"product_id":"micasense-altum-pt-with-skyport","title":"MicaSense Altum-PT with DJI M300\/M350 SkyPort Kit","description":"\u003ch2\u003eMicaSense Altum-PT with SkyPort Kit: Integrated multispectral, panchromatic, and thermal sensing with direct DJI SkyPort mounting\u003c\/h2\u003e\n\u003cp\u003eThe MicaSense Altum-PT with SkyPort Kit is a complete enterprise imaging bundle designed for DJI Matrice 300 RTK and Matrice 350 RTK aircraft. It combines the Altum-PT multispectral, panchromatic, and radiometric thermal sensor with the dedicated DJI SkyPort Kit for Altum-PT, enabling direct aircraft mounting and stable alignment.\u003c\/p\u003e\n\u003cp\u003eThis bundle simplifies integration while delivering synchronized spectral and thermal datasets in a single flight, supporting professional agriculture, environmental monitoring, and research workflows that demand accurate, repeatable, and spatially precise data.\u003c\/p\u003e\n\u003ch3\u003eSynchronized multispectral, panchromatic, and thermal sensing system\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMultispectral imaging: 2064 × 1544 resolution, 3.2 MP per band\u003c\/li\u003e\n\u003cli\u003ePanchromatic imaging: 4112 × 3008 resolution, 12 MP sensor\u003c\/li\u003e\n\u003cli\u003eThermal imaging: 320 × 256 radiometric thermal resolution\u003c\/li\u003e\n\u003cli\u003eThermal sensor: FLIR LWIR radiometric thermal module\u003c\/li\u003e\n\u003cli\u003eThermal spectral range: 7.5–13.5 µm wavelength band\u003c\/li\u003e\n\u003cli\u003eSynchronized capture: All sensors triggered simultaneously\u003c\/li\u003e\n\u003cli\u003ePixel-aligned outputs: Multispectral, panchromatic, and thermal aligned\u003c\/li\u003e\n\u003cli\u003eIntegrated DLS 2: Downwelling light sensor included with Altum-PT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh-resolution outputs for detailed spatial and spectral analysis\u003c\/h3\u003e\n\u003cp\u003eAltum-PT is engineered for workflows requiring fine spatial detail and consistent alignment across data types. The 12 MP panchromatic sensor supports pan-sharpened outputs reaching 1.25 cm per pixel at 60 m (200 ft) and 2.49 cm per pixel at 120 m (400 ft).\u003c\/p\u003e\n\u003cp\u003eMultispectral imagery at 3.2 MP per band remains aligned to this spatial detail, enabling precise vegetation analysis. Thermal imagery is captured simultaneously at 320 × 256 resolution, allowing direct correlation between reflectance metrics and surface temperature without temporal offsets.\u003c\/p\u003e\n\u003ch3\u003eThermal insight combined with reflectance-based vegetation metrics\u003c\/h3\u003e\n\u003cp\u003eThe integrated FLIR LWIR radiometric thermal sensor adds a critical analytical layer to Altum-PT datasets. Operating across the 7.5–13.5 µm spectral range, the thermal sensor supports irrigation analysis, soil moisture assessment, and crop stress detection.\u003c\/p\u003e\n\u003cp\u003eWith thermal data captured in sync with multispectral and panchromatic imagery, users can evaluate temperature patterns alongside vegetation indices in a single dataset. This integration improves interpretability and supports more informed decision-making for water management and plant health monitoring.\u003c\/p\u003e\n\u003ch3\u003eAircraft compatibility and SkyPort-based integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDJI Matrice 300 RTK: Fully supported via included SkyPort Kit\u003c\/li\u003e\n\u003cli\u003eDJI Matrice 350 RTK: Fully supported via included SkyPort Kit\u003c\/li\u003e\n\u003cli\u003eDJI Matrice 400: Not supported at this time\u003c\/li\u003e\n\u003cli\u003eSkyPort adapter included: Direct mechanical and electrical interface\u003c\/li\u003e\n\u003cli\u003eSecure mounting: Maintains stable sensor alignment during flight\u003c\/li\u003e\n\u003cli\u003eSimplified installation: Reduces setup time on supported aircraft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional applications supported by the bundle\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIrrigation scheduling: Identify water distribution issues using spectral and thermal data\u003c\/li\u003e\n\u003cli\u003ePlant disease detection: Detect early stress indicators before visual symptoms\u003c\/li\u003e\n\u003cli\u003ePlant phenotyping: Capture consistent datasets across growth stages\u003c\/li\u003e\n\u003cli\u003eYield estimation: Analyze crop vigor and spatial variability\u003c\/li\u003e\n\u003cli\u003eWater stress prediction: Combine thermal and multispectral indicators\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring: Support research-grade vegetation analysis\u003c\/li\u003e\n\u003cli\u003ePrecision agriculture mapping: Enable high-resolution, repeatable surveys\u003c\/li\u003e\n\u003cli\u003eLong-term studies: Maintain consistent radiometric performance over time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAltum-PT vs RedEdge-P (Key Comparison)\u003c\/h3\u003e\n\u003cstyle\u003e\n  .comparison-table {\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 14px;\n  }\n  .comparison-table th,\n  .comparison-table td {\n    border: 1px solid #e5e5e5;\n    padding: 10px 12px;\n    vertical-align: top;\n    text-align: left;\n  }\n  .comparison-table thead th {\n    background-color: #f7f7f7;\n    font-weight: 600;\n  }\n  .comparison-table tbody tr:nth-child(even) {\n    background-color: #fafafa;\n  }\n  @media (max-width: 768px) {\n    .comparison-table th,\n    .comparison-table td {\n      font-size: 13px;\n      padding: 8px;\n    }\n  }\n\u003c\/style\u003e\n\u003ctable class=\"comparison-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eAltum-PT\u003c\/th\u003e\n\u003cth\u003eRedEdge-P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary purpose\u003c\/td\u003e\n\u003ctd\u003eCombined multispectral, thermal, and RGB sensing\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution multispectral and RGB imaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal imaging\u003c\/td\u003e\n\u003ctd\u003eYes – radiometric FLIR LWIR (320 × 256)\u003c\/td\u003e\n\u003ctd\u003eNo thermal sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultispectral bands\u003c\/td\u003e\n\u003ctd\u003e5 bands (Blue, Green, Red, Red Edge, NIR)\u003c\/td\u003e\n\u003ctd\u003e5 bands per sensor; up to 10 bands with dual-camera setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRGB \/ panchromatic sensor\u003c\/td\u003e\n\u003ctd\u003e12 MP panchromatic\u003c\/td\u003e\n\u003ctd\u003e5.1 MP panchromatic (pan-sharpened)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultispectral GSD @120 m\u003c\/td\u003e\n\u003ctd\u003e5.28 cm per pixel\u003c\/td\u003e\n\u003ctd\u003e7.7 cm per pixel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePan-sharpened resolution\u003c\/td\u003e\n\u003ctd\u003e2.49 cm per pixel @120 m (≈1.25 cm @60 m)\u003c\/td\u003e\n\u003ctd\u003e≈3.98 cm per pixel @120 m (≈2 cm with pan-sharpening)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal GSD @120 m\u003c\/td\u003e\n\u003ctd\u003e33.5 cm per pixel\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapture rate\u003c\/td\u003e\n\u003ctd\u003eUp to 2 images per second (all bands, RAW)\u003c\/td\u003e\n\u003ctd\u003eUp to 3 images per second (RAW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eCFexpress card\u003c\/td\u003e\n\u003ctd\u003eCFexpress card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiometric calibration\u003c\/td\u003e\n\u003ctd\u003eIntegrated multispectral and thermal calibration\u003c\/td\u003e\n\u003ctd\u003eMultispectral calibration with dual calibration panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical system weight\u003c\/td\u003e\n\u003ctd\u003e≈577 g\u003c\/td\u003e\n\u003ctd\u003e≈745 g (dual-sensor configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest-fit use cases\u003c\/td\u003e\n\u003ctd\u003eIrrigation diagnostics, water stress, soil moisture, thermal crop analysis\u003c\/td\u003e\n\u003ctd\u003eVegetation indices, crop vigor, classification, time-series analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"margin-top: 16px; padding: 14px 16px; background: #f6f8fa; border: 1px solid #e4e7ec; border-radius: 10px;\"\u003e\n\u003cdiv style=\"font-weight: bold; margin-bottom: 6px;\"\u003eWhich should I choose?\u003c\/div\u003e\n\u003cp style=\"margin: 8px 0 0 0;\"\u003eChoose \u003cstrong\u003eAltum-PT\u003c\/strong\u003e if your workflow requires thermal data alongside multispectral imagery, such as irrigation optimization, water stress detection, or soil moisture analysis. Choose \u003cstrong\u003eRedEdge-P\u003c\/strong\u003e if your priority is higher spectral flexibility, faster capture rates, and advanced vegetation indices for crop monitoring, classification, and long-term time-series analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDesigned for enterprise deployment and operational reliability\u003c\/h3\u003e\n\u003cp\u003eThis bundle is built for professional UAV programs that require dependable integration and consistent data quality. The included SkyPort Kit ensures secure mounting on supported DJI enterprise aircraft, while integrated downwelling light sensing improves radiometric consistency under changing illumination.\u003c\/p\u003e\n\u003cp\u003eTogether, the Altum-PT sensor and SkyPort adapter form a deployment-ready system that supports repeatable, high-quality data collection for long-term agricultural and environmental operations.\u003c\/p\u003e\n\u003cp\u003eThe MicaSense Altum-PT with SkyPort Kit delivers a complete sensing and mounting solution for teams that require accurate, repeatable, and actionable aerial data.\u003c\/p\u003e\n\u003cp\u003eAvailable from DSLRPros, backed by enterprise UAS specialists who support integration, deployment, and long-term program success.\u003c\/p\u003e","brand":"MicaSense","offers":[{"title":"Default Title","offer_id":49490156912879,"sku":"B-MICA-ALT-PT-SKY-M300","price":17944.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/9445\/6815\/files\/MicaSense_Altum_PT_with_Skyport.webp?v=1777889377","url":"https:\/\/www.thenomadsessentials.com\/products\/micasense-altum-pt-with-skyport","provider":"The Nomads Essentials","version":"1.0","type":"link"}